Bo JIN, Ya-guang ZHU, Wei LI, et al. A differential control method for the proportional directional valve[J]. Frontiers of Information Technology & Electronic Engineering, 2014, 15(10): 892-902.
Bo JIN, Ya-guang ZHU, Wei LI, et al. A differential control method for the proportional directional valve[J]. Frontiers of Information Technology & Electronic Engineering, 2014, 15(10): 892-902. DOI: 10.1631/jzus.C1400056.
研究目的
2
对于由两个比例电磁铁控制的比例方向阀,常用的控制方法仅给其中一个电磁铁供电,因此,阀的性能受到比例电磁铁特性影响,如死区、小电流时的力增益非线性等,且此影响无法用简单的死区电流补偿消除。本文提出差动控制方法(differential control method),以改善比例电磁铁的性能。
创新要点
2
在建立比例阀电磁铁非线性模型的基础上,提出了差动控制策略,建立差动控制器输出互成差动关系的两路控制信号,分别激励比例阀的左右两个比例电磁铁,以总体力增益恒定为优化目标选取最佳工作点,从而减小比例阀电磁铁的非线性,改善比例方向阀性能。
方法提亮
2
同时驱动比例方向阀的两个比例电磁铁,使两路控制信号满足差动关系,合理配置静态工作点使两路比例电磁铁的合力线性度最高,并通过阀芯位移反馈实现对阀芯位置的闭环控制。
重要结论
2
实验结果表明,差动控制算法能够有效改善比例阀电磁铁的非线性特性,提高比例方向阀阀心位移的控制精度与响应速度。
For the proportional directional valve controlled by two proportional solenoids
the normal control method (NCM) energizes only one solenoid at a time. The performance of the valve is greatly influenced by the nonlinearity of the proportional solenoid
such as dead zone and low force gain with a small current
and this effect cannot be eliminated by a simple dead-zone current compensation. To avoid this disadvantage
we propose the differential control method (DCM). By employing DCM
the controller outputs differential signals to simultaneously energize both solenoids of the proportional valve
and the operating point is found by analyzing the force output of the two solenoids to make a minimum variation of the current force gain. The comparisons of the valve response characteristics are made between NCM and DCM by nonlinear dynamic simulation and experiments. Simulation and experimental results show that by using DCM
the frequency response of the valve is greatly enhanced
especially when the input is small
which means that the dynamic characteristics of the proportional valve are improved.
R. Amirante , , , G. Del Vescovo , , , A. Lippolis . . Flow forces analysis of an open center hydraulic directional control valve sliding spool . . Energ. Conv. Manag. , , 2006 . . 47 ( ( 1 ): ): 114 - - 131 . . DOI: 10.1016/j.enconman.2005.03.010 http://doi.org/10.1016/j.enconman.2005.03.010 . .
R. Amirante , , , A. Innone , , , L.A. Catalano . . Boosted PWM open loop control of hydraulic proportional valves . . Energ. Conv. Manag. , , 2008 . . 49 ( ( 8 ): ): 2225 - - 2236 . . DOI: 10.1016/j.enconman.2008.02.001 http://doi.org/10.1016/j.enconman.2008.02.001 . .
R. Amirante , , , L.A. Catalano , , , C. Poloni , , , 等 . . Fluiddynamic design optimization of hydraulic proportional directional valves . . Eng. Optim. , , 2014 . . 46 ( ( 10 ): ): 1295 - - 1314 . . DOI: 10.1080/0305215X.2013.836638 http://doi.org/10.1080/0305215X.2013.836638 . .
F. Bu , , , B. Yao . . Performance improvement of proportional directional control valves: methods and experiments . . Proc. ASME Dynamic Systems and Control Division , , 2000 . . p.297 - - 304 . . . .
G. Del Vescovo , , , A. Lippolis . . Three-dimensional analysis of flow forces on directional control valves . . Int. J. Fluid Power , , 2003 . . 4 ( ( 2 ): ): 15 - - 24 . . DOI: 10.1080/14399776.2003.10781162 http://doi.org/10.1080/14399776.2003.10781162 . .
D. Devarajan , , , S. Stanton , , , B. Knorr . . Multi-domain modeling and simulation of a linear actuation system . . Proc. Int. Workshop on Behavioral Modeling and Simulation , , 2003 . . p.76 - - 81 . . DOI: 10.1109/BMAS.2003.1249861 http://doi.org/10.1109/BMAS.2003.1249861 . .
K.F. Elmer , , , C.R. Gentle . . A parsimonious model for the proportional control valve . . Proc. Inst. Mech. Eng. C J. Mech. Eng. Sci. , , 2001 . . 215 ( ( 11 ): ): 1357 - - 1363 . . DOI: 10.1243/0954406011524739 http://doi.org/10.1243/0954406011524739 . .
J.B. Gamble , , , N.D. Vaughan . . Comparison of sliding mode control with state feedback and PID control applied to a proportional solenoid valve . . J. Dynam. Syst. Meas. Contr. , , 1996 . . 118 ( ( 3 ): ): 434 - - 438 . . DOI: 10.1115/1.2801163 http://doi.org/10.1115/1.2801163 . .
B. Jin , , , Y.G. Zhu , , , W. Li . . PID parameters tuning of proportional directional valve based on multiple orthogonal experiments method: method and experiments . . Appl. Mech. Mater. , , 2013 . . 325 1166 - - 1169 . . DOI: 10.4028/www.scientific.net/AMM.325-326.1166 http://doi.org/10.4028/www.scientific.net/AMM.325-326.1166 . .
T. Kajima . . Development of a high-speed solenoid valve-investigation of the energizing circuits . . IEEE. Trans. Ind. Electron. , , 1993 . . 40 ( ( 4 ): ): 428 - - 435 . . DOI: 10.1109/41.232232 http://doi.org/10.1109/41.232232 . .
M. Khoshzaban Zavarehi , , , P.D. Lawrence , , , F. Sassani . . Nonlinear modeling and validation of solenoid-controlled pilot-operated servovalves . . IEEE/ASME Trans. Mechatron. , , 1999 . . 4 ( ( 3 ): ): 324 - - 334 . . DOI: 10.1109/3516.789690 http://doi.org/10.1109/3516.789690 . .
X. Kong , , , H. Wang . . A spool displacement control system of proportional valve based on digital observer . . Key Eng. Mater. , , 2010 . . 455 110 - - 115 . . DOI: 10.4028/www.scientific.net/KEM.455.110 http://doi.org/10.4028/www.scientific.net/KEM.455.110 . .
K. Li , , , M.A. Mannan , , , M. Xu , , , 等 . . Electro-hydraulic proportional control of twin-cylinder hydraulic elevators . . Contr. Eng. Pract. , , 2001 . . 9 ( ( 4 ): ): 367 - - 373 . . DOI: 10.1016/S0967-0661(01)00003-X http://doi.org/10.1016/S0967-0661(01)00003-X . .
Y. Liu , , , Z. Dai , , , X. Xu , , , 等 . . Multi-domain modeling and simulation of proportional solenoid valve . . J. Cent. South Univ. Technol. , , 2011 . . 18 ( ( 5 ): ): 1589 - - 1594 . . DOI: 10.1007/s11771-011-0876-2 http://doi.org/10.1007/s11771-011-0876-2 . .
M. Ruderman , , , A. Gadyuchko . . Phenomenological modeling and measurement of proportional solenoid with stroke-dependent magnetic hysteresis characteristics . . IEEE Int. Conf. on Mechatronics , , 2013 . . p.180 - - 185 . . DOI: 10.1109/ICMECH.2013.6518532 http://doi.org/10.1109/ICMECH.2013.6518532 . .
E. Sampson , , , S. Habibi , , , R. Burton , , , 等 . . Effect of controller in reducing steady-state error due to flow and force disturbances in the electrohydraulic actuator system . . Int. J. Fluid Power , , 2004 . . 5 ( ( 2 ): ): 57 - - 66 . . DOI: 10.1080/14399776.2004.10781192 http://doi.org/10.1080/14399776.2004.10781192 . .
N.D. Vaughan , , , J.B. Gamble . . The modeling and simulation of a proportional solenoid valve . . J. Dynam. Syst. Meas. Contr. , , 1996 . . 118 ( ( 1 ): ): 120 - - 125 . . DOI: 10.1115/1.2801131 http://doi.org/10.1115/1.2801131 . .
Q. Yuan , , , P.Y. Li . . An experimental study on the use of unstable electrohydraulic valves for control . . American Control Conf. , , 2002 . . p.4843 - - 4848 . . DOI: 10.1109/ACC.2002.1025425 http://doi.org/10.1109/ACC.2002.1025425 . .
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621