FOLLOWUS
Department of Electrical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
School of Electrical and Computer Engineering, University of Tehran, Tehran, Iran
[ "Mahmoud MODARESI, E-mail: m.modares@srbiau.ac.ir" ]
Hamid LESANI, E-mail: lesani@ut.ac.ir
收稿:2016-11-06,
修回:2018-;2-15,
纸质出版:2018-02
Scan QR Code
Mahmoud MODARESI, Hamid LESANI. 电力系统中对称和/或不对称故障的限流器阻抗优化新方法[J]. 信息与电子工程前沿(英文), 2018,19(2):297-307.
Mahmoud MODARESI, Hamid LESANI. New method to determine optimum impedance of fault current limiters for symmetrical and/or asymmetrical faults in power systems[J]. Frontiers of Information Technology & Electronic Engineering, 2018, 19(2): 297-307.
Mahmoud MODARESI, Hamid LESANI. 电力系统中对称和/或不对称故障的限流器阻抗优化新方法[J]. 信息与电子工程前沿(英文), 2018,19(2):297-307. DOI: 10.1631/FITEE.1601689.
Mahmoud MODARESI, Hamid LESANI. New method to determine optimum impedance of fault current limiters for symmetrical and/or asymmetrical faults in power systems[J]. Frontiers of Information Technology & Electronic Engineering, 2018, 19(2): 297-307. DOI: 10.1631/FITEE.1601689.
为给电力网络设计者选择故障限流器(fault currentl imiters,FCLs)的阻抗类型和阻值,提出一种基于其在网络中的位置计算最佳FCL阻值的新方法。由于阻抗的复杂性,需同时考虑FCL阻抗实部和虚部的代价。FCL阻抗优化的目标函数,是以最小化代价最大限度减少故障电流。虽然最佳FCL阻抗值的计算受其在网络中位置的影响,但选取FCL位置的方法并非本文重点。该FCL阻抗优化方法可用于任何具有对称和/或不对称故障的网络。以一个14总线IEEE网络为例解释该过程。该网络采用的最优FCL阻抗是同时考虑FCL阻抗实部和虚部的大范围代价计算得到的。
To select the type and value of the impedance of fault current limiters (FCLs) for power network designers
we introduce a new method to calculate the optimum value of FCL impedance depending on its position in the network. Due to the complexity of its impedance
the costs of both real and imaginary parts of FCL impedance are considered. The optimization of FCL impedance is based on a goal function that maximizes the reduction of the fault current while minimizing the costs. While the position of FCL in the network has an effect on the calculation of the optimum impedance value
the method for selecting FCL location is not the focus of this study. The proposed method for optimizing FCL impedance can be used for every network that has symmetrical and/or asymmetrical faults. We use a 14-bus IEEE network as an example to explain the process. The optimum FCL impedance used in this network is calculated by considering the vast range of costs for both real and imaginary parts of FCL impedance.
A Abramovitz , , , KM Smedley . . Survey of solid-state fault current limiters . . IEEE Trans Power Electron , , 2012 . . 27 ( ( 6 ): ): 2770 - - 2782 . . DOI: 10.1109/TPEL.2011.2174804 http://doi.org/10.1109/TPEL.2011.2174804 . .
S Alaraifi , , , MS El Moursi , , , HH Zeineldin . . Optimal allocation of HTS-FCL for power system security and stability enhancement . . IEEE Trans Power Syst , , 2013 . . 28 ( ( 4 ): ): 4702 - - 4711 . . DOI: 10.1109/TPWRS.2013.2273539 http://doi.org/10.1109/TPWRS.2013.2273539 . .
R Christie . . Power System Test Case Archive , , 2012 . . https://www.ee.washington.edu/research/pstca/pf14/pg_tca14bus.htm https://www.ee.washington.edu/research/pstca/pf14/pg_tca14bus.htm . .
D Cvoric , , , SWH de Haan , , , JA Ferreira , , , 等 . . New three-phase inductive FCL with common core and trifilar windings . . IEEE Trans Power Del , , 2010 . . 25 ( ( 4 ): ): 2246 - - 2254 . . DOI: 10.1109/TPWRD.2010.2051688 http://doi.org/10.1109/TPWRD.2010.2051688 . .
QB Dam , , , APS Meliopoulos . . Failure probability methodology for overdutied circuit breakers . . 38 th IEEE North American Power Symp , , 2006 . . p.667 - - 672 . . DOI: 10.1109/NAPS.2006.359644 http://doi.org/10.1109/NAPS.2006.359644 . .
QB Dam , , , APS Meliopoulos . . Reliability implications of increased fault currents and breaker failures. iREP Symp on Bulk Power System Dynamics and Control -Ⅶ . . Revitalizing Operational Reliability, , , 2007 . . p.1 - - 8 . . DOI: 10.1109/IREP.2007.4410540 http://doi.org/10.1109/IREP.2007.4410540 . .
QB Dam , , , APS Meliopoulos , , , GJ Cokkinides . . A breaker-oriented fault analysis methodology . . Int Trans Electr Energy Syst , , 2013 . . 23 ( ( 7 ): ): 1071 - - 1082 . . DOI: 10.1002/etep.1638 http://doi.org/10.1002/etep.1638 . .
G Didier , , , J LȦvȺque . . Influence of fault type on the optimal location of superconducting fault current limiter in electrical power grid . . Int J Electr Power Energy Syst , , 2014 . . 56 279 - - 285 . . DOI: 10.1016/j.ijepes.2013.11.018 http://doi.org/10.1016/j.ijepes.2013.11.018 . .
G Didier , , , CH Bonnard , , , T Lubin , , , 等 . . Comparison between inductive and resistive sFCL in terms of current limitation and power system transient stability . . Electr Power Syst Res , , 2015 . . 125 150 - - 158 . . DOI: 10.1016/j.epsr.2015.04.002 http://doi.org/10.1016/j.epsr.2015.04.002 . .
MS El Moursi , , , R Hegazy . . Novel technique for reducing the high fault currents and enhancing the security of ADWEA power system . . IEEE Trans Power Syst , , 2013 . . 28 ( ( 1 ): ): 140 - - 148 . . DOI: 10.1109/TPWRS.2012.2207746 http://doi.org/10.1109/TPWRS.2012.2207746 . .
M Fotuhi-Firuzabad , , , F Aminifar , , , I Rahmati . . Reliability study of HV substations equipped with the fault current limiter . . IEEE Trans Power Del , , 2012 . . 27 ( ( 2 ): ): 610 - - 617 . . DOI: 10.1109/TPWRD.2011.2179122 http://doi.org/10.1109/TPWRD.2011.2179122 . .
Y Guo , , , Y Yokomizu , , , T Matsumura . . Design guidelines of a flux-lock superconducting fault current limiter with AC magnetic field coil for a 6 . . 6-kV distribution system. Electr Eng Jpn , , 2001 . . 135 ( ( 4 ): ): 17 - - 25 . . DOI: 10.1002/eej.1038 http://doi.org/10.1002/eej.1038 . .
MR Haghifam , , , A Ghaderi , , , M Abapour . . Enhancement circuit breaker reliability by using fault current limiter . . IEEE Power & Energy Society General Meeting , , 2009 . . p.1 - - 5 . . DOI: 10.1109/PES.2009.5275260 http://doi.org/10.1109/PES.2009.5275260 . .
K Hongesombut , , , Y Mitani , , , K Tsuji . . Optimal location assignment and design of superconducting fault current limiters applied to loop power systems . . IEEE Trans Appl Supercond , , 2003 . . 13 ( ( 2 ): ): 1828 - - 1831 . . DOI: 10.1109/TASC.2003.812901 http://doi.org/10.1109/TASC.2003.812901 . .
Heidary A Hossen , , , H Radmanesh , , , SH Fathi , , , 等 . . Series transformer based diode-bridge-type solid state fault current limiter . . Front Inform Technol Electron Eng , , 2015 . . 16 ( ( 9 ): ): 769 - - 784 . . DOI: 10.1631/FITEE.1400428 http://doi.org/10.1631/FITEE.1400428 . .
H Javadi . . Fault current limiter using a series impedance combined with bus sectionalizing circuit breaker . . Int J Electr Power Energy Syst , , 2011 . . 33 ( ( 3 ): ): 731 - - 736 . . DOI: 10.1016/j.ijepes.2010.11.023 http://doi.org/10.1016/j.ijepes.2010.11.023 . .
SY Kim , , , IS Bae , , , JO Kim . . An optimal location for superconducting fault current limiter considering distribution reliability . . IEEE Power and Energy Society General Meeting , , 2010 . . p.1 - - 5 . . DOI: 10.1109/PES.2010.5588064 http://doi.org/10.1109/PES.2010.5588064 . .
SY Kim , , , WW Kim , , , JO Kim . . Evaluation of distribution reliability with superconducting fault current limiter . . 10 th IEEE Int Conf on Environment and Electrical Engineering , , 2011 . . p.1 - - 5 . . DOI: 10.1109/EEEIC.2011.5874570 http://doi.org/10.1109/EEEIC.2011.5874570 . .
SY Kim , , , WW Kim , , , JO Kim . . Determining the location of superconducting fault current limiter considering distribution reliability . . IET Gener Transm Distr , , 2012 . . 6 ( ( 3 ): ): 240 - - 246 . . DOI: 10.1049/iet-gtd.2011.0287 http://doi.org/10.1049/iet-gtd.2011.0287 . .
L Kovalsky , , , X Yuan , , , K Tekletsadik , , , 等 . . Applications of superconducting fault current limiters in electric power transmission systems . . IEEE Trans Appl Supercond , , 2005 . . 15 ( ( 2 ): ): 2130 - - 2133 . . DOI: 10.1109/TASC.2005.849471 http://doi.org/10.1109/TASC.2005.849471 . .
T Matsumura , , , H Shimizu , , , Y Yokomizu . . Design guideline of flux-lock type HTS fault current limiter for power system application . . IEEE Trans Appl Supercond , , 2001 . . 11 ( ( 1 ): ): 1956 - - 1959 . . DOI: 10.1109/77.920235 http://doi.org/10.1109/77.920235 . .
SC Mukhopadhyay , , , M Iwahara , , , S Yamada , , , 等 . . Investigation of the performances of a permanent magnet biased fault current limiting reactor with a steel core . . IEEE Trans Magn , , 1998 . . 34 ( ( 4 ): ): 2150 - - 2152 . . DOI: 10.1109/20.706833 http://doi.org/10.1109/20.706833 . .
SB Naderi , , , M Jafari , , , M Tarafdar Hagh . . Parallel-resonance-type fault current limiter . . IEEE Trans Ind Electron , , 2013 . . 60 ( ( 7 ): ): 2538 - - 2546 . . DOI: 10.1109/TIE.2012.2196899 http://doi.org/10.1109/TIE.2012.2196899 . .
M Nagata , , , K Tanaka , , , H Taniguchi . . FCL location selection in large scale power system . . IEEE Trans Appl Supercond , , 2001 . . 11 ( ( 1 ): ): 2489 - - 2494 . . DOI: 10.1109/77.920370 http://doi.org/10.1109/77.920370 . .
H Saadat . . Power System Analysis . . WCB/McGraw-Hill , , 1999 . . .
HC Seo , , , CH Kim , , , SB Rhee , , , 等 . . Superconducting fault current limiter application for reduction of the trans-former inrush current: a decision scheme of the optimal insertion resistance . . IEEE Trans Appl Supercond , , 2010 . . 20 ( ( 4 ): ): 2255 - - 2264 . . DOI: 10.1109/TASC.2010.2048214 http://doi.org/10.1109/TASC.2010.2048214 . .
SAA Shahriari , , , AY Varjani , , , MR Haghifam . . Cost reduction of distribution network protection in presence of distributed generation using optimized fault current limiter allocation . . Int J Electr Power Energy Syst , , 2012 . . 43 ( ( 1 ): ): 1453 - - 1459 . . DOI: 10.1016/j.ijepes.2012.06.071 http://doi.org/10.1016/j.ijepes.2012.06.071 . .
M Stemmle , , , C Neumann , , , F Merschel , , , 等 . . Analysis of unsymmetrical faults in high voltage power systems with superconducting fault current limiters . . IEEE Trans Appl Supercond , , 2007 . . 17 ( ( 2 ): ): 2347 - - 2350 . . DOI: 10.1109/TASC.2007.899136 http://doi.org/10.1109/TASC.2007.899136 . .
JH Teng , , , CN Lu . . Optimum fault current limiter placement with search space reduction technique . . IET Gener Transm Distr , , 2010 . . 4 ( ( 4 ): ): 485 - - 494 . . DOI: 10.1049/iet-gtd.2009.0340 http://doi.org/10.1049/iet-gtd.2009.0340 . .
H Yamaguchi , , , T Kataoka . . Current limiting characteristics of transformer type superconducting fault current limiter with shunt impedance . . IEEE Trans Appl Supercond , , 2007 . . 17 ( ( 2 ): ): 1919 - - 1922 . . DOI: 10.1109/TASC.2007.898494 http://doi.org/10.1109/TASC.2007.898494 . .
H Yousefi , , , F Aminifar , , , M Mirzaie . . Reliability assessment of HV substations equipped with fault current limiter considering changes of failure rate of components . . IET Gener Transm Distr , , 2016 . . 10 ( ( 7 ): ): 1504 - - 1509 . . DOI: 10.1049/iet-gtd.2014.1250 http://doi.org/10.1049/iet-gtd.2014.1250 . .