
FOLLOWUS
1.National Key Laboratory of Science and Technology on Autonomous Underwater Vehicle, Harbin Engineering University, Harbin 150001, China
2.State Key Laboratory of Robot and Systems, Harbin Institute of Technology, Harbin 150001, China
3.Institute of Robotics and Mechatronics, German Aerospace Center, DLR, Wessling 82230, Germany
[ "Hai HUANG, E-mail: haihus@163.com" ]
收稿:2011-09-01,
修回:2012-;9-11,
纸质出版:2012-10
Scan QR Code
An anthropomorphic controlled hand prosthesis system[J]. 信息与电子工程前沿(英文), 2012,13(10):769-780.
Hai HUANG, Hong LIU, Nan LI, et al. An anthropomorphic controlled hand prosthesis system[J]. Frontiers of Information Technology & Electronic Engineering, 2012, 13(10): 769-780.
An anthropomorphic controlled hand prosthesis system[J]. 信息与电子工程前沿(英文), 2012,13(10):769-780. DOI: 10.1631/jzus.C1100257.
Hai HUANG, Hong LIU, Nan LI, et al. An anthropomorphic controlled hand prosthesis system[J]. Frontiers of Information Technology & Electronic Engineering, 2012, 13(10): 769-780. DOI: 10.1631/jzus.C1100257.
Based on HIT/DLR (Harbin Institute of Technology/Deutsches Zentrum für Luft- und Raumfahrt) Prosthetic Hand Ⅱ
an anthropomorphic controller is developed to help the amputees use and perceive the prosthetic hands more like people with normal physiological hands. The core of the anthropomorphic controller is a hierarchical control system. It is composed of a top controller and a low level controller. The top controller has been designed both to interpret the amputee's intensions through electromyography (EMG) signals recognition and to provide the subject–prosthesis interface control with electro-cutaneous sensory feedback (ESF)
while the low level controller is responsible for grasp stability. The control strategies include the EMG control strategy
EMG and ESF closed loop control strategy
and voice control strategy. Through EMG signal recognition
10 types of hand postures are recognized based on support vector machine (SVM). An anthropomorphic closed loop system is constructed to include the customer
sensory feedback system
EMG control system
and the prosthetic hand
so as to help the amputee perform a more successful EMG grasp. Experimental results suggest that the anthropomorphic controller can be used for multi-posture recognition
and that grasp with ESF is a cognitive dual process with visual and sensory feedback. This process while outperforming the visual feedback process provides the concept of grasp force magnitude during manipulation of objects.
A.B. Ajiboye , , , R.F.F. Weir . . A heuristic fuzzy logic approach to EMG pattern recognition for multifunctional prosthetic control . . IEEE Trans. Neur. Syst. Rehabil. Eng. , , 2005 . . 13 ( ( 3 ): ): 280 - - 291 . . DOI: 10.1109/TNSRE.2005.847357 http://doi.org/10.1109/TNSRE.2005.847357 . .
C. Antfolk , , , C. Balkenius , , , G. Lundborg , , , B. Rosén , , , F. Sebelius . . Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system . . BioMed. Eng. OnLine , , 2010 . . 9 50 DOI: 10.1186/1475-925X-9-50 http://doi.org/10.1186/1475-925X-9-50 . .
A. Bicchi . . Hand for dexterous manipulation and robust grasping:a difficult road toward simplicity . . IEEE Trans. Robot. Autom. , , 2000 . . 16 ( ( 6 ): ): 652 - - 662 . . DOI: 10.1109/70.897777 http://doi.org/10.1109/70.897777 . .
S. Bitzer , , , P. van der Smagt . . Learning EMG Control of a Robotic Hand:Towards Active Prostheses . . IEEE Int. Conf. on Robotics and Automation , , 2006 . . p.2819 - - 2823 . . DOI: 10.1109/ROBOT.2006.1642128 http://doi.org/10.1109/ROBOT.2006.1642128 . .
C.J.C. Burges . . A tutorial on support vector machines for pattern recognition . . Data Min. Knowl. Disc. , , 1998 . . 2 ( ( 2 ): ): 121 - - 167 . . DOI: 10.1023/A:1009715923555 http://doi.org/10.1023/A:1009715923555 . .
C. Castellini , , , P. van der Smagt . . Surface EMG in advanced hand prosthetics . . Biol. Cybern. , , 2009 . . 100 ( ( 1 ): ): 35 - - 47 . . DOI: 10.1007/s00422-008-0278-1 http://doi.org/10.1007/s00422-008-0278-1 . .
R.G.E. Clement , , , K.E. Bugler , , , C.W. Oliver . . Bionic prosthetic hands:a review of present technology and future aspirations . . Surgeon , , 2011 . . 9 ( ( 6 ): ): 336 - - 340 . . DOI: 10.1016/j.surge.2011.06.001 http://doi.org/10.1016/j.surge.2011.06.001 . .
P. Dario , , , C. Laschi , , , M.C. Carrozza , , , E. Guglielmelli , , , G. Teti , , , B. Massa , , , M. Zecca , , , D. Taddeucci , , , F. Leoni . . An Integrated Approach for the Design and Development of a Grasping and Manipulation System in Humanoid Robotics . . IEEE Int. Conf. on Robotics & Automation , , 2002 . . 1 1 - - 7 . . . .
N.S. Davidovics , , , G.Y. Fridman , , , B. Chiang , , , C.C. Della Santina . . Effects of biphasic current pulse frequency, amplitude, duration, and interphase gap on eye movement responses to prosthetic electrical stimulation of the vestibular nerve . . IEEE Trans. Neur. Syst. Rehabil. Eng. , , 2011 . . 19 ( ( 1 ): ): 84 - - 94 . . DOI: 10.1109/TNSRE.2010.2065241 http://doi.org/10.1109/TNSRE.2010.2065241 . .
N. Dechev , , , W.L. Cleghorn , , , S. Naumann . . Multiple finger, passive adaptive grasp prosthetic hand . . Mech. Mach. Theory , , 2001 . . 36 ( ( 10 ): ): 1157 - - 1173 . . DOI: 10.1016/S0094-114X(01)00035-0 http://doi.org/10.1016/S0094-114X(01)00035-0 . .
C.C. Della Santina , , , A.A. Migliaccio , , , A.H. Patel . . A multichannel semicircular canal neural prosthesis using electrical stimulation to restore 3-D vestibular sensation . . IEEE Trans. Biomed. Eng. , , 2007 . . 54 ( ( 6 ): ): 1016 - - 1030 . . DOI: 10.1109/TBME.2007.894629 http://doi.org/10.1109/TBME.2007.894629 . .
M.A. Diftler , , , C.J. Culbert , , , R.O. Ambrose , , , R.Jr. Platt , , , W.J. Bluethmann . . Evolution of the NASA/DARPA Robonaut Control System . . IEEE Int. Conf. on Robotics and Automation , , 2003 . . 2 2543 - - 2548 . . DOI: 10.1109/ROBOT.2003.1241975 http://doi.org/10.1109/ROBOT.2003.1241975 . .
A. Edsinger-Gonzales . . Design of a Compliant and Force Sensing Hand for a Humanoid Robot . . Proc. Int. Conf. on Intelligent Manipulation and Grasping , , 2004 . . p.291 - - 295 . . . .
D. Graupe , , , J. Salahi , , , K. Kohn . . Multifunction prosthesis and orthosis control via micro-computer identification of temporal pattern differences in single-site myoelectric signals . . J. Biomed. Eng. , , 1982 . . 4 ( ( 1 ): ): 17 - - 22 . . DOI: 10.1016/0141-5425(82)90021-8 http://doi.org/10.1016/0141-5425(82)90021-8 . .
W.M.Jr. Grill , , , J.T. Mortimer . . The effect of stimulus pulse duration on selectivity of neural stimulation . . IEEE Trans. Biomed. Eng. , , 1996 . . 43 ( ( 2 ): ): 161 - - 166 . . DOI: 10.1109/10.481985 http://doi.org/10.1109/10.481985 . .
H. Huang , , , L. Jiang , , , D.W. Zhao , , , J.D. Zhao , , , H.G. Cai , , , H. Liu , , , P. Meusel , , , B. Willberg , , , G. Hirzinger . . The Development on a New Biomechatronic Prosthetic Hand Based on Under-Actuated Mechanism . . IEEE/RSJ Int. Conf. on Intelligent Robots and Systems , , 2006 . . p.3791 - - 3796 . . DOI: 10.1109/IROS.2006.281765 http://doi.org/10.1109/IROS.2006.281765 . .
H. Huang , , , L. Jiang , , , Y.J. Pang , , , S.C. Shi , , , Q.R. Tang , , , D.P. Yang , , , H. Liu . . Observer-based dynamic control of an underactuated hand . . Adv. Robot. , , 2010 . . 24 ( ( 1-2 ): ): 123 - - 137 . . DOI: 10.1163/016918609X12586151361812 http://doi.org/10.1163/016918609X12586151361812 . .
H.P. Huang , , , C.Y. Chen . . Development of a Myoelectric Discrimination System for a Multi-degree Prosthetic Hand . . Proc. IEEE Int. Conf. on Robotics and Automation , , 1999 . . p.2392 - - 2397 . . . .
S.C. Jacobsen , , , E.K. Iversen , , , D.F. Knutti , , , R.T. Johnson , , , K.B. Biggers . . Design of the Utah/MIT Dextrous Hand . . IEEE Int. Conf. on Robotics and Automation , , 2001 . . p.1520 - - 1532 . . . .
H. Kawasaki , , , T. Mouri , , , S. Ito . . Toward Next Stage of Kinetic Humanoid Hand . . 10th Int. Symp. on Robotics with Applications , , 2004 . . p.129 - - 134 . . . .
S.S. Keerthi , , , C.J. Lin . . Asymptotic behaviors of support vector machines with Gaussian kernel . . Neur. Comput. , , 2003 . . 15 ( ( 7 ): ): 1667 - - 1689 . . DOI: 10.1162/089976603321891855 http://doi.org/10.1162/089976603321891855 . .
T. Kuiken , , , P. Marasco , , , B. Lock , , , R. Harden , , , J. Dewald . . Redirection of cutaneous sensation from the hand to the chest skin of human amputees with targeted reinnervation . . PNAS , , 2007 . . 104 ( ( 50 ): ): 20061 - - 20066 . . DOI: 10.1073/pnas.0706525104 http://doi.org/10.1073/pnas.0706525104 . .
P. Kumar , , , A. Sebastian , , , C. Potluri , , , A. Urfer , , , D.S. Naidu , , , M.P. Schoen . . Towards Smart Prosthetic Hand:Adaptive Probability Based Skeletan Muscle Fatigue Model . . 32nd Annual Int. Conf. IEEE EMBS , , 2010 . . p.1316 - - 1319 . . DOI: 10.1109/IEMBS.2010.5626388 http://doi.org/10.1109/IEMBS.2010.5626388 . .
H.C. Lee , , , B.J. Kang , , , E.C. Lee , , , K.R. Park . . Finger vein recognition using weighted local binary pattern code based on a support vector machine . . J. Zhejiang Univ.-Sci. C (Comput. & Electron.) , , 2010 . . 11 ( ( 7 ): ): 514 - - 524 . . DOI: 10.1631/jzus.C0910550 http://doi.org/10.1631/jzus.C0910550 . .
S. Lee , , , G.N. Saridis . . The control of a prosthetic arm by EMG pattern recognition . . IEEE Trans. Autom. Control , , 1984 . . 29 ( ( 4 ): ): 290 - - 320 . . DOI: 10.1109/TAC.1984.1103521 http://doi.org/10.1109/TAC.1984.1103521 . .
H. Liu , , , P. Meusel , , , N. Seitz , , , B. Willberg , , , G. Hirzinger , , , M.H. Jin , , , Y.W. Liu , , , R. Wei , , , Z.W. Xie . . The modular multisensory DLR-HIT-Hand . . Mech. Mach. Theory , , 2007 . . 42 ( ( 5 ): ): 612 - - 625 . . DOI: 10.1016/j.mechmachtheory.2006.04.013 http://doi.org/10.1016/j.mechmachtheory.2006.04.013 . .
Y.H. Liu , , , H.P. Huang , , , C.H. Weng . . Recognition of electromyographic signals using cascaded kernel learning machine . . IEEE/ASME Trans. Mechatron. , , 2007 . . 12 ( ( 3 ): ): 253 - - 264 . . DOI: 10.1109/TMECH.2007.897253 http://doi.org/10.1109/TMECH.2007.897253 . .
F. Lotti , , , P. Tiezzi , , , G. Vassura , , , L. Biagiotti , , , G. Palli , , , C. Melchiorri . . Development of UB Hand 3:Early Results . . Proc. IEEE Int. Conf. on Robotics and Automation , , 2005 . . p.4488 - - 4493 . . DOI: 10.1109/ROBOT.2005.1570811 http://doi.org/10.1109/ROBOT.2005.1570811 . .
C.S. Loucks , , , V.J. Johnson , , , P.T. Boissiere , , , G.P. Starr , , , J.P.H. Steele . . Modeling and Control of the Stanford/JPL Hand . . Int. Conf. on Robotics and Automation , , 1987 . . p.573 - - 578 . . . .
D.R. Merrill , , , M. Bikson , , , J.G. Jefferys . . Electrical stimulation of excitable tissue:design of efficacious and safe protocols . . J. Neurosci. Methods , , 2005 . . 141 ( ( 2 ): ): 171 - - 198 . . DOI: 10.1016/j.jneumeth.2004.10.020 http://doi.org/10.1016/j.jneumeth.2004.10.020 . .
S. Micera , , , J. Carpaneto , , , S. Raspopovic . . Control of hand prostheses using peripheral information . . IEEE Rev. Biomed. Eng. , , 2010 . . 3 48 - - 68 . . DOI: 10.1109/RBME.2010.2085429 http://doi.org/10.1109/RBME.2010.2085429 . .
C. Pylatiuk , , , S. Mounier , , , A. Kargov , , , S. Schulz , , , G. Bretthauer . . Progress in the Development of a Multifunctional Hand Prosthesis . . Proc. 26th Annual Int. Conf. IEEE EMBS , , 2004 . . p.4260 - - 4263 . . . .
B. Rosen , , , H. Ehrsson , , , C. Antfolk , , , C. Cipriani , , , F. Sebelius , , , G. Lundborg . . Referral of sensation to an advanced humanoid robotic hand prosthesis . . J. Plast. Reconstr. Surg. Hand Surg. , , 2009 . . 43 ( ( 5 ): ): 260 - - 266 . . DOI: 10.3109/02844310903113107 http://doi.org/10.3109/02844310903113107 . .
R.N. Scott , , , R.R. Caldwell , , , R.H. Britain . . Sensory-feedback system compatible with myoelectric control . . Med. Biol. Eng. Comput. , , 1980 . . 18 ( ( 1 ): ): 65 - - 69 . . DOI: 10.1007/BF02442481 http://doi.org/10.1007/BF02442481 . .
S. Shimizu , , , M. Shimojo , , , S. Sato , , , Y. Seki , , , A. Takahashi , , , Y. Inukai , , , M. Yoshioka . . The Relationship Between Human Grip Types and Force Distribution Pattern in Grasping . . Proc. 8th Int. Conf. on Advanced Robotics , , 1997 . . p.299 - - 304 . . . .
C.E. Stepp , , , Y. Matsuoka . . Object manipulation improvements due to single session training outweigh the differences among stimulation sites during vibrotactile feedback . . IEEE Trans. Neur. Syst. Rehabil. Eng. , , 2011 . . 19 ( ( 6 ): ): 677 - - 685 . . DOI: 10.1109/TNSRE.2011.2168981 http://doi.org/10.1109/TNSRE.2011.2168981 . .
C.L. Taylor , , , R.J. Schwarz . . The anatomy and mechanics of the human hand . . Artif. Limbs , , 1955 . . 2 22 - - 35 . . . .
T. Wimböck , , , C. Ott , , , G. Hirzinger . . Impedance Behaviors for Two-Handed Manipulation:Design and Experiments . . IEEE Int. Conf. on Robotics and Automation , , 2007 . . p.4182 - - 4189 . . DOI: 10.1109/ROBOT.2007.364122 http://doi.org/10.1109/ROBOT.2007.364122 . .
J.D. Zhao , , , Z.W. Xie , , , L. Jiang , , , H.G. Cai , , , H. Liu , , , G. Hirzinger . . Levenberg-Marquardt Based Neural Network Control for a Five-Fingered Prosthetic Hand . . Proc. IEEE Int. Conf. on Robotics and Automation , , 2005 . . p.4482 - - 4487 . . DOI: 10.1109/ROBOT.2005.1570810 http://doi.org/10.1109/ROBOT.2005.1570810 . .
J.D. Zhao , , , W.X. Xie , , , L. Jiang , , , H.G. Cai , , , H. Liu , , , G. Hirzinger . . A Five-Fingered Underactuated Prosthetic Hand Control Scheme . . First IEEE/RAS-EMBS Int. Conf. on Biomedical Robotics and Biomechatronics , , 2006 . . p.995 - - 1000 . . DOI: 10.1109/BIOROB.2006.1639221 http://doi.org/10.1109/BIOROB.2006.1639221 . .
L. Zollo , , , S. Roccella , , , R. Tucci , , , B. Siciliano , , , E. Guglielmelli , , , M.C. Carrozza , , , P. Dario . . BioMechatronic Design and Control of an Anthropomorphic Artificial Hand for Prosthetics and Robotic Applications . . First Int. Conf. on Biomedical Robotics and Biomechatronics , , 2006 . . p.402 - - 407 . . DOI: 10.1109/BIOROB.2006.1639121 http://doi.org/10.1109/BIOROB.2006.1639121 . .
L. Zollo , , , S. Roccella , , , R. Tucci , , , B. Siciliano , , , E. Guglielmelli , , , M.C. Carrozza , , , P. Dario . . Biomechatronic design and control of an anthropomorphic artificial hand for prosthetic and robotic applications . . IEEE/ASME Trans. Mechatron. , , 2007 . . 12 ( ( 4 ): ): 418 - - 429 . . DOI: 10.1109/TMECH.2007.901936 http://doi.org/10.1109/TMECH.2007.901936 . .
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621